Draper DA50 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
- 6 -
1. CAUTION:You must remove the plastic transit
bung from the oil sump and replace it with the
dip stick (provided) before any initial use of the
compressor to avoid any long term problems.
Connect the compressor to the power supply.
Always turn the machine on and off by means of
the appropriate switch ✪✌ Fig.1. located on top
of the pressure switch box.
2. Check that the reservoir drain valve is closed
✫✌Fig.2.
3. These compressors are controlled by a pressure
switch assembly ✬✌which automatically cuts
off the power supply to the motor when the
maximum operating pressure is reached and
restarts the compressor when the compressor
drops below the pre-set minimum.
✪✌ PRESSURE GAUGE -
indicates air pressure in receiver.
✫✌ ON/OFF SWITCH
✬✌ MOTOR
✭✌ RESERVOIR INSPECTION PLUG
✮✌ MOTOR COWLING -
covers/protects moving parts.
✯✌ AIR RECEIVER -
stores air.
✰✌ AIR OUTLET VALVE -
releases air from the reservoir.
✱✌ THERMAL OVERLOAD
PROTECTION RESET SWITCH
✲✌
OVERLOAD SAFETY RELEASE VALVE
✳✌ RESERVOIR DRAIN VALVE
KNOW YOUR AIR COMPRESSOR
OPERATION
✪✌
✫✌
✲✌
✮✌
✰✌
✯✌
✱✌
✬✌
✭✌
✳✌
✳✌
✫✌
✬✌
Fig.1.
Fig.2.