Access Electric Projection Screen by Draper
Copyright © 2013 Draper Inc. Form Access_Inst13 Printed in U.S.A
Hanging Screen
When locating viewing surface and checking clearance for screen operation,
remember surface is centered in the length of the case. Regardless of
mounting method used, the following points apply:
1 Mounting brackets are shipped attached to the case. Engage each bracket
with top of housing as shown below and tighten set screws. A bracket
should be within 18" of each end of screen case. Brackets can be removed
and case mounted with lag screws through top of case (holes drilled on
site).
2 Screen should be positively and securely supported so that vibration or
even abusive pulling on viewing surface will not weaken installation.
3 Installer must insure that fasteners used are of adequate strength and
suitable for the mounting surface chosen. Supporting hardware (chains,
cables,
3
/
8
" rods, etc.) must be essentially vertical.
4 Entire bottom of case must be readily accessible after installation is
complete.
5 Front, back and top of case must be straight—not forced to warp or bow.
6 If case is painted on location, removal of roller/fabric assembly is
recommended prior to painting. If not removed, slot on bottom of case
should be shielded to protect viewing surface from paint splatters or
overspray.
Electrical Connections
Screen operates on 110-120V, 60 Hz. current.
Junction box is located just above the bottom access panel at left end of
screen (standard, right end may be specified).
Remove the bottom access panel for access to the junction box cover. (See
Bottom Access Panel Removal instructions below). Remove four (4) hex head
screws that secure the cover to the junction box to expose the red, black, and
white pigtail leads and the green ground wire per wiring diagram on page 3.
If optional low voltage control or video interface control is specified and factory
installed, please refer to wiring diagrams on page 4.
Screen is shipped with internal wiring complete and control switch(es) fully
boxed. Wire to connect screen to switch(es) and switch(es) to power supply
should be furnished by installer. Connections should be made in accordance
with attached wiring diagram, and wiring should comply with national and
local electrical codes.
All operating switches should be “off” before power is connected.
Caution
1 Read instructions through completely before proceeding; keep them
for future reference. Follow instructions carefully. Installation contrary to
instructions invalidates warranty. Care in mounting and correct operation
will mean long and satisfactory service from your Draper screen.
2 Before removing screen from crate, check for damage and to make sure
all parts are included.
3 Allow enough access to remove front cover should fabric become
damaged or should other service be required.
4 Screen should be installed level (using a carpenter’s level).
5 Nothing should be fastened to screen dowel or viewing surface.
6 Operating switch(es) is packed separately in screen carton. Do not
discard with packing material.
7 Screen operates on 110-120V, 60 Hz. 1.1 amp current draw.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
Bottom Access Panel Installation/Removal
Bottom access panel hooks over the lower inside edge of the screen housing
and then is pivoted downward until the engagement brackets on each end of
the bottom panel click into place with the ball detents on each endcap. Make
sure bottom access panel clicks in place at each end of its length.
Remove bottom access panel by pushing up at each corner of panel adjacent
to slot in bottom of the housing.
With bottom access panel angled up approximately at 20° it can be lifted off of
the lip of the housing and then lowered out of the housing completely.
With bottom access panel
angled up approx. 20 degrees,
engage hook on the panel
with lip of the housing
Using the hook and lip as a pivot,
pull the panel downward until the
engagement brackets click into
place with the ball detent
on each endcap
Engagement bracket
(one on each end of the
bottom access panel)
Access case as seen from below
®
If you encounter any difficulties installing or servicing your Access screen, call your
dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3)
and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Typical
Installation
Alternate
Installation
(additional
set of
brackets
required but
not included)
Slots along top of case permit
brackets to be set at an angle
Case dimensions
on page 3.
Dowel
Shipping
Bracket
Remove
shipping
brackets
before
operating
screen.
Bottom flange of Access housing
Bottom access panel pushup
points for panel removal
Caution: Beware of pinch
points at ends of closure
US Patent Nos.
6,137,629; 6,421,175;
6,532,109; 6,816,308;
7,559,707
7
/
8
" electrical cutout
These instructions are meant as a guide only. They do not imply any responsibility
on the part of the manufacturer for improper installation or faulty workmanship at
the jobsite.
7 Do not seal unit in ceiling until electrical connections have been made and
screen has been operated successfully.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Caution: Beware of pinch

Installation/Operating InstructionsAccess Electric Projection Screen by DraperCopyright © 2013 Draper Inc. Form Access_Inst13 Printed in U.S.AHangin

Page 2 - Operation

Access Instructions by Draper page 2 of 4Motorized Roller/Fabric InstallationPlease note: When ordering a motor with built-in Low Voltage Controller,

Page 3 - Case Dimensions

Access Instructions by Draper page 3 of 4Mounting hardware supplied by othersCase Dimensions43/4"21/8"13/16"Engagement bracket (one on

Page 4 - Motor Data Cable

Access Instructions by Draper page 4 of 4Built-In VIC-12*Built-In VIC-115*Green/YellowBlackWhiteGreenGreenRedBlackWhiteGround#2 Up#1 DownCommonJacket

Comments to this Manuals

No comments