Limit Adjustments (Built-in Low Voltage Motors)
(Height adjustments are made from wall switch)
Please Note: Screen limits are factory set for optimum performance of the
screen. Any adjustment of these limits could void the warranty. Please
check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off position before adjusting limit
switches.
Connect the switch to the motor via the terminal blocks, or via the
modular port using four conductor modular cable. When using modular
cable, the cable connectors MUST NOT be crimped in reverse, as with
standard telephone cable.
Set the slide switch to the lower position. Press and hold the DOWN button
on the switch to move the viewing surface to the desired lower limit. If the
screen moves in the opposite direction,
release the DOWN button and press and
hold down the STOP button for four seconds.
This will reverse the opera-
tion of the UP and DOWN
switches.
3 Move slider switch into
center position.Wait a
couple of seconds.
Please Note: If you move the slider switch
from down to up in one motion it sets the two
limits in the same position.
Set the slide switch to the higher position.
Move the viewing surface to the desired upper
limit by pressing and holding the UP button on the wall switch.
Return the slide switch to the center position to return to normal operation.
To set the viewing surface to an alternate format position, move the viewing
surface to the desired position and press the STOP button. Press and hold
the STOP button for at least three seconds to record the position.
Please Note: Pressing and releasing the UP button on the switch will move
the screen to its upper limit. Pressing and releasing the DOWN button will
move the screen to its lower limit.
While the motor is in motion, pressing the STOP button for less than two
seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the view-
ing surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at rest or in mo-
tion, for at least three seconds will record a new alternate format position.
Premier by Draper
Case Dimensions
Page 2 of 3
Tab-Tension Adjustment
Procedure for Premier
Determine which side requires adjustment.
Secure dowel with one hand.
Caution: Do not touch or bend surface.
Using Phillips-head screwdriver,
depress spring-loaded adjustment screw
(see drawing) and slowly turn clockwise to
tighten tension, or counterclockwise to
loosen tension. The screw adjusts in
¼ turn increments. Adjust only one
increment (¼ turn).
If problem is not corrected, leave screen in
position for 24 hours to allow surface
material to stretch into position.
If problem still is not corrected, repeat steps 2 and 3.
Dowel
Adjustment
Screw
Te nsioning
Cable
5
1
/
4
"
1
13
/
16
"
5
7
/
8
"
1"
15
/
16
"
7
/8" dia.
electrical
connection
hole
Mounting
hole
2
1
/8"
Types of Installation
Appropriate hardware
provided by installer.
Suspended
Wall
Appropriate hardware
provided by installer.
Optional Ceiling Opening
Trim Kit (Dims-Side View)
2
1
/8"
2
1
/16
"
4"
6
3
/4"
1
1
/16"
8"
.draperinc.com
(765) 987-799
If using "S"
Hooks )by
others), be
sure to crimp
both ends of
the "S" Hooks.
Screen Needs to Run Up More
Run screen down about 1' and turn off.
With the up switch on, turn the UP limit screw (II) counterclockwise (three
turns of screw equals ½ roller revolution).
Repeat steps 1 and 2 until desired position is reached.
CAUTION: Do NOT allow the dowel to wrap up over the roller when the
screen is running up! This could damage the screen.
the +5V
UP
5V
COM
DWN
U
P
D
O
W
N
C
O
M
M
O
N
5V
Motor Data Cable
plugged in here
Built-in Low Voltage Motor: Switch-to-Motor—
Dry Contacts or Data Cable connection
Please Note: This
Splitter/Jack is
located inside the
motor-end endcap
of your screen. To
access, remove
access panel from
endcap.
Back of wall switch.
Please Note: Although both
Dry Contact and Data Cable
connections are shown, you
should only use one connec-
tion type per motor.
Data Cables to switches or
to additional motors can
be plugged into any of the
three open jacks.
POSITION
FUNCTION
DOWN
UP
CENTER
Set LOWER limit
Set UPPERlimit
Normal Operation
STO P
To Motor
with
Built-In
Low Voltage
Slide
Switch
Back View
U
p
D
o
w
n
C
o
m
m
o
n
+
5V
DC
To Motor
with
Built-In
Low Voltage
POSITION
FUNCTION
DOWN
UP
CENTER
Set LOWER limit
Set UPPERlimit
Normal Operation
STO P
To Motor
with
Built-In
Low Voltage
Slide
Switch
Back View
U
p
D
o
w
n
C
o
m
m
o
n
+
5V
DC
To Motor
with
Built-In
Low Voltage
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
Page view 1
1 2 3

Comments to this Manuals

No comments