CONNECTING THE COMPRESSOR TO THE POWER SUPPLY:
To eliminate the possibility of an electric shock your machine has been fitted with a BS approved, non
rewireable moulded plug and cable which incorporates a fuse, the value of which is indicated on the pin
face of the plug. Should the fuse need to be replaced an approved BS1362 fuse must be used of the
same rating, marked thus . The fuse cover is
detachable, never use the plug with the cover omitted. If a replacement fuse cover is required, ensure it is
of the same colour as that visible on the pin face of the plug (i.e. red). Fuse covers are available from your
Draper Tools stockist.
If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the cable should now be
suitably prepared and the correct type of plug fitted. See below.
*WARNING:
A plug with bare flexible wires exposed is hazardous if engaged in a live power socket outlet.
WARNING: THIS APPLIANCE MUST BE EARTHED.
Green and Yellow - Earth, Blue - Neutral, Brown - Live.
As these colours may not correspond with the coloured markings identifying the terminals in your plug,
proceed as follows.:
The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter 'E' or by the earth symbol or coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter 'N' or
coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked with the letter 'L' or
coloured red or brown.
N.B. Three phase machines must be connected by a qualified electrician.
EXTENSION LEAD CHART:
Extension lead sizes shown assure a voltage drop of not more than 5% at rated load of tool.
POWER SUPPLY
- 5 -
3 6 10 13
Extension cable length Wire Size mm
2
7.5m 0.75 0.75 1.0 1.25
15m 0.75 0.75 1.0 1.5
22.5m 0.75 0.75 1.0 1.5
30m 0.75 0.75 1.25 1.5
45m 0.75 1.25 1.5 2.5
Ampere rating