Installation Instructions
Premier Electric Projection Screen by Draper
Caution
Read instructions through completely before proceeding.
Follow instructions carefully. Installation contrary to instructions invalidates
warranty.
Screen should be accessible for complete removal should fabric become
damaged or should other service be required.
Screen should be installed level (using a carpenter’s level).
Nothing should be fastened to screen dowel or viewing surface.
Operating switch(es) packed separately in screen carton. Do not discard
with packing material.
Screen operates on 110-120V, 60 Hz., 1.1 amp current draw.
Hanging Screen
General:
When locating viewing surface and checking clearance for screen’s operation,
remember surface is centered in case. Handle case carefully to protect finish.
Regardless of mounting method, screen should be positively and securely
supported so that vibration or even abusive pulling on the viewing surface will not
cause case to work loose or fall. Installer must insure that fasteners used are of
adequate strength and suitable for the mounting surface chosen.
Suspended Installation:
Suspend screens from holes in endcaps as shown. “S” hooks, chains (or cable)
and turnbuckles should be provided by installer. "S" hooks should go through the
rear holes on the endcap sides (see drawing on page 2), and both ends of the
"S" hooks should be crimped for additional safety. Chains should be attached to
beams or other structural members. Turnbuckles should be adjusted so screen
hangs level.
Wall Installation:
Mount screen through holes in back of endcaps as shown. Installer should furnish
screws, toggle bolts, molly bolts, nylon or lead anchors as required.
Wall or Ceiling Installation with Floating Brackets:
Floating brackets should be located on studs or joists. The bracket then attaches
at any almost any point along the case. For details, see separate instruction sheet
that ships with the Floating Wall Bracket.
Recessed Installation:
Recess should permit access for removal of screen if necessary. Screen may be
mounted as in suspended or wall installation. Optional Ceiling Opening Trim Kit
also available; see diagram on page 2 and separate instruction sheet (included
with Ceiling Opening Trim Kit). The Ceiling Opening Trim Kit is for use in an acous-
tical, drop ceiling only. Not recommended for drywall or hard ceilings.
Electrical Connections
Screen operates on 110-120V, 60 Hz., 1.1 amp current draw. Duty cycle: On 28
seconds/Off 4 minutes. Junction box is located inside left endcap and cover plate
is secured to endcap with two screws which may be removed with a Torx-head or
small straight-blade screwdriver. Junction box contains terminal strip, per wiring
diagram on reverse.
Screen is shipped with internal wiring complete and control switch(es) fully boxed.
Wire connecting screen to switch(es) and switch(es) to power supply should be
furnished by installer. Do NOT wire motors in parallel. Please Note: Screen must
be installed in accordance with the requirements of the Local Building Codes, the
Canadian Electrical Code (CEC), CAN/CSA C22.1 and the National Electric Code
(NEC), NFPA 70. An appropriate disconnect device shall be provided as part of the
building installation.
Copyright © 2013 Draper Inc. Form Premier_Inst13 Printed in U.S.A.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
Operation
CAUTION—Important Instructions: Shipping support brackets must be
removed from each end of dowel during initial operation, before screen is operated
in UP direction. After screen is installed, lower viewing surface to access screws
holding brackets to dowel. Loosen hex head screw, remove bracket and retighten
screw at each end of dowel. Raise and lower viewing surface several times to
confirm satisfactory operation. If viewing surface does not operate properly, turn
power off and check electrical connections.
110-120V Single Station Control—3-position up-off-down switch permits
operation to be stopped at any point. Factory adjusted limit switches automatically
stop screen when fully down or fully up.
110-120V Multiple Station ControlSwitches are similar in appearance to
110-120V Single Station Control. Screen stops when switch is released and
may be restarted in either direction. Factory adjusted limit switches stop screen
automatically when fully down or fully up.
24V ControlThree-button up-stop-down switch (es) stop at any point desired,
operate in any sequence. Factory adjusted limit switches automatically stop screen
when fully down or fully up.
Key Operated SwitchingTwo kinds of key-operated switches are optionally
available with this unit. The key-operated power supply switch controls power to
the screen and switches. When it is “off”, the switches will not operate screen. Key
may be removed from the switch in either “on” or “off position. A three-position
key switch permits the screen to be operated directly by key. In this case, the
screen’s operator must always have a key.
RS232/Ethernet—Serial communication and network communication optionally
available with wall switches, RF or IR remote.
Plug & Play
TM
Provided with handheld IR remote control transmitter and 10'
(3m) cord. No wiring necessary except to connect to RS232. Screen is equipped
with a handheld remote or 3-position operating switch (see below). Three positions
(up-off-down) permit operation to be stopped at any point. Factory adjusted limit
switches automatically stop screen when fully down or fully up.
Continued on page 2
Dowel
Shipping
Bracket
®
Screen Case
Back
Ceiling Tile
(By others)
If you encounter any difficulties installing or servicing your Premier screen, call your
dealer or Draper, Inc. Spiceland, Indiana, U.S.A., (765) 987-7999 or fax (765) 987-7142.
Limit Adjustments (Standard/Quiet Motors)
Please Note: Screen limits are factory set for optimum performance of the
screen. Any adjustment of these limits could void the warranty. Please
check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off position before adjusting limit
switches.
The motor limit screws are normally located on the audience left of screen roller,
and the viewing surface rolls off the back of the roller. If the viewing surface is
coming off the front of the roller (motor on left), or the motor is on the audience
right of the screen roller (with viewing surface rolling off the back), reverse the
below instructions.
"DOWN" LIMIT ADJUSTMENT
To Reduce Screen Drop
Raise screen surface about 1' above desired setting and turn off.
Turn the DOWN limit screw (I) clockwise (three screw turns = ½ roller
revolution).
Test by running screen down and repeat steps 1 and 2 until desired position
is reached.
To Increase Screen Drop
Run screen to the down limit.
With the down switch on, turn the DOWN limit screw (I) counterclockwise
(three turns of screw equals ½ roller revolution) to increase drop.
Test by running screen up about 1' and back down to new down limit.
Repeat steps 2 and 3 until desired position is reached.
"UP" LIMIT ADJUSTMENT
Screen is Running Too Far Up
Lower screen surface about 1' below desired setting and turn off.
Turn the UP limit screw (II) clockwise (three screw turns = ½ roller
revolution).
Test by running screen up.
Repeat steps 1 through 3 until desired position is reached.
All operating switches should be “Off” before power is connected.
Plug-in power cord option available with built-in low voltage motor.
For Reconfiguration/Conversion of Non-detachable Power Cord to
Field Wiring for Models PRE-28, PRE-29 and PRE-30 Only:
1 Disconnect cord plug from outlet.
2 Remove junction box cover.
3 Disconnect wire nuts from black, white and green wires.
4 Remove power cord and strain relief from screen.
5 Connect the black motor wire to "hot" supply wire.
6 Connect white motor wire to "neutral" supply wire.
7 Connect green/yellow wire to "ground" supply wire.
8 Replace junction box cover.
Ceiling Trim Kit
Floating Mounting Bracket
These instructions are meant as a guide only. They do not imply any responsibility
on the part of the manufacturer for improper installation or faulty workmanship at
the jobsite.
Page view 0
1 2 3

Summary of Contents

Page 1 - Installation Instructions

Installation InstructionsPremier Electric Projection Screen by Draper Caution Read instructions through completely before proceeding. Follow instruc

Page 2 - Types of Installation

Limit Adjustments (Built-in Low Voltage Motors)(Height adjustments are made from wall switch)Please Note: Screen limits are factory set for optimum pe

Page 3 - Page 3 of 3

Premier by DraperPage 3 of 3www.draperinc.com(765) 987-7999(Wiring Diagrams Standard and Quiet Motors)Single Station Control Internal Screen WiringWhi