Draper SGC4 Instruction Manual Page 104

  • Download
  • Add to my manuals
  • Print
  • Page
    / 124
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 103
Motor Name:
660R2
RPM: 14
Volts: 120 Amps: 2.5
Min. Shade Width: 48” om
Standard Motor Lead Length: n/a
Lead Type:
18-3 w/ground
Plug Options: Wago w or w/o wall plate
Anderson w or w/o wall plate
Limit Type: Turn Screw
Special Notes:
This is the standard motor for a Colossal.
Installation Procedure:
1. Mount complete unit
2. Test motor and adjust limits
3. Let electrician tie into electrical
4. Program controls
5. Test shade operation through switching
Controls that motor can wire into: Isolating Relays, SC1 controllers, GC4 control, SGC4 control,
SPGC4 control, Keyed Wall Switch, SP/DT toggle switch, DP/DT toggle switch, Animeo. For
questions on other controls ask Draper, Inc.
Used in: Colossal Only
Optional Lead Lengths: No Options
Part No: C047.032
Product (s) Used In: Colossal
Roller Diameter Choices: 6”
Parallel Wire:
No
Torque in Nm: 60
Page 104 of 124
Page view 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 123 124

Comments to this Manuals

No comments